Produk

Produk

Low Voltage Withdrawable Switchgear Panel
  • Low Voltage Withdrawable Switchgear PanelLow Voltage Withdrawable Switchgear Panel
  • Low Voltage Withdrawable Switchgear PanelLow Voltage Withdrawable Switchgear Panel
  • Low Voltage Withdrawable Switchgear PanelLow Voltage Withdrawable Switchgear Panel

Low Voltage Withdrawable Switchgear Panel

Kanggo distribusi daya industri, kontrol motor, lan manajemen energi listrik, Zhejiang Usune Electric Co., Ltd. nyedhiyakake solusi Panel Switchgear sing Bisa Ditarik Tegangan Rendah. Peralatan kasebut dirancang kanggo sistem AC 50–60Hz kanthi tegangan kerja sing dirating nganti 660V lan nggunakake konfigurasi modular kanggo nampung macem-macem sirkuit mlebu, metu, motor, lan kompensasi. Kabutuhan voltase sedheng bisa ditindakake kanthi kapisah karo Panel Switchgear sing Bisa Ditarik Tegangan Rendah.
Rating: 5.0
(Rating Count: 1)

Kanggo proyek sing mbutuhake sawetara jinis beban listrik sing kudu dikelola saka siji sistem distribusi voltase rendah terpusat, Panel Switchgear sing Bisa Ditarik Tegangan Rendah minangka pilihan sing cocog. Kabinet ndhukung konfigurasi kanthi unit distribusi daya, unit kontrol motor, lan fungsi kompensasi faktor daya adhedhasar diagram listrik pelanggan, tinimbang ngandelake susunan tetep siji. Persyaratan voltase medium ing proyek sing padha bisa ditutupi dening Panel Switchgear sing Bisa Ditarik Tegangan Rendah.

Low Voltage Withdrawable Switchgear Panel

Konfigurasi Sistem

Jinis beban sing beda-beda-peralatan produksi, motor, lampu, peralatan tambahan, lan beban reaktif-biasane urip bebarengan ing sistem listrik voltase rendah sing gedhe, lan saben-saben mbutuhake pangreksan lan pengaturan kontrol dhewe. Switchgear modular Usune mulane bisa dikonfigurasi kanthi fungsi sirkuit: Pusat Distribusi Daya (PC) kanggo daya mlebu lan metu, Pusat Kontrol Motor (MCC) kanggo feeder motor, lan kabinet ganti rugi kanggo manajemen daya reaktif. Engineers mangkono bisa mbangun switchboard watara struktur mbukak nyata saka project.


Distribusi Daya

Ing sisih panrima lan distribusi saka sistem voltase kurang lenggah kabinèt PC. Miturut paramèter listrik sing dibutuhake, bisa ngemot pemutus sirkuit seri Emax, MT, 3WN, AH, ME lan komponen liyane sing cocog karo desain sing disetujoni. Jalur produksi hilir, trafo, peralatan tambahan, sistem bangunan, lan beban liyane diwenehake saka bagean distribusi. Where project wis sawetara feeder, saben sirkuit bisa glethakaken metu kanggo cocog karo syarat saiki lan pangayoman dirating sawijining, kang tansah jaringan distribusi sakabèhé luwih gampang kanggo ngatur.


Kontrol Motor

Antarane komponen paling gedhe ing sistem listrik industri yaiku beban motor: pompa, penggemar, kompresor, konveyor, alat mesin, lan peralatan produksi bisa uga mbutuhake sirkuit motor khusus. Laci gedhe lan cilik ing konfigurasi MCC nampung macem-macem syarat feeder motor, lan piranti saklar utama saben sirkuit bisa dadi pemutus sirkuit cetakan cetakan kanthi kapasitas dhuwur utawa saklar beban Rotary kanthi sekring. Sirkuit motor mula diklompokake saka sirkuit distribusi daya umum nalika kontrol terpusat saka sistem listrik ditahan.


Kontrol Faktor Daya

Kompensasi daya reaktif bisa uga dibutuhake ing fasilitas industri kanthi akeh motor lan beban induktif. Bagean ganti rugi bisa dikonfigurasi dening Usune kanthi fungsi kompensasi faktor daya manual, otomatis, utawa remot, kanthi metode kontrol sing dipilih kanggo cocog karo sistem manajemen listrik pelanggan. Kanthi njaga peralatan ganti rugi sing kapisah saka distribusi umum lan sirkuit motor, susunan kabinet luwih cedhak karo strategi manajemen daya sakabèhé pelanggan.


Tatanan Modular

Sing paling penting ing sistem voltase rendah sing bisa ditarik yaiku dudu struktur kabinet, nanging kapasitas kanggo ngatur fungsi listrik sing beda ing siji sistem sing terkoordinasi. Daya mlebu ditangani dening bagean PC, sing nyebarake listrik menyang feeder hilir, konfigurasi pemutus sing dipilih miturut syarat sistem saiki lan proteksi. Sirkuit sing gegandhengan karo motor ditangani dening bagean MCC, ing ngendi ukuran laci diatur supaya cocog karo rating motor lan jumlah feeder. Daya reaktif dikelola dening bagean ganti rugi, bisa dikonfigurasi kanggo operasi manual, otomatis, utawa remot. Gumantung saka syarat proyek, telung wilayah fungsional kasebut bisa dirancang kanthi kapisah utawa digabungake dadi siji papan switch voltase rendah.


Load-Based Pilihan

Tinimbang tampilan kabinet, beban listrik kudu dadi titik wiwitan nalika milih sistem switchgear voltase rendah. Insinyur ing proyek distribusi daya biasane ngonfirmasi voltase mlebu, arus sing dirating, jumlah feeder sing metu, tingkat sirkuit cendhak, kapasitas motor, lan syarat ekspansi ing mangsa ngarep. Nomer motor lan rating dadi faktor kunci kanggo nemtokake konfigurasi MCC kanggo fasilitas intensif motor. Yen beban reaktif penting, kapasitas kompensasi sing dibutuhake lan cara kontrol uga kudu ditimbang. Pendekatan adhedhasar beban kasebut mbantu mesthekake konfigurasi Panel Switchgear sing Bisa Ditarik Tegangan Rendah cocog karo karakteristik operasi nyata fasilitas kasebut.


Aplikasi

Fungsi Distribusi nemtokake cara Panel Switchgear ditarik Tegangan Rendah dikonfigurasi, saéngga bisa ngladeni macem-macem industri lan lingkungan listrik.

Industri Manufaktur

Ing pabrik, daya tekan peralatan produksi, motor, sistem tambahan, lan mesin proses liwat konfigurasi PC lan MCC.

Fasilitas Petrokimia

Pompa, kipas angin, kompresor, lan sistem motor-driven liyane umume ing pabrik petrokimia; sirkuit kontrol motor darmabakti bisa glethakaken metu ing bagean MCC.

Tanduran Metalurgi

Motor daya dhuwur lan macem-macem jalur produksi khas fasilitas baja lan metalurgi, ing ngendi distribusi modular ngidini sirkuit feeder khusus nangani macem-macem beban.

Sarana Transportasi

Pasokan listrik peralatan, sistem tambahan, peralatan ventilasi, lan beban listrik liyane ing infrastruktur transportasi bisa dilayani kanthi distribusi voltase rendah terpusat.

Bangunan Komersial

Kanggo manajemen feeder terpusat lan pasokan peralatan listrik, bangunan dhuwur lan pembangunan omah bisa gumantung ing lemari distribusi voltase rendah.

Proyek Energi

Distribusi mlebu, feeder metu, sirkuit motor, lan kompensasi daya reaktif bisa digabungake ing sistem voltase rendah terpadu ing fasilitas sing gegandhengan karo daya.

Cas-space Rocket Launch ProjectCas-space Rocket Launch Project

Kondisi Operasi

Panel Switchgear sing Bisa Ditarik Tegangan Rendah standar dirancang kanggo suhu sekitar -5 ° C lan +40 ° C, kanthi suhu rata-rata ora ngluwihi +35 ° C sajrone 24 jam.

Kita nemtokake ketinggian instalasi standar ≤2000m. Udhara ing saubengé kudu relatif resik, lan disaranake nimbang langkah-langkah sing cocog ing ngendi asor lan fluktuasi suhu bisa nyebabake kondensasi.

Kanggo transportasi lan panyimpenan, kita nggunakake sawetara suhu saka -25 ° C nganti + 55 ° C, kanthi paparan jangka pendek nganti +70 ° C ora luwih saka 24 jam.

Yen peralatan dibutuhake kanggo platform minyak lepas pantai, pembangkit listrik tenaga nuklir, utawa lingkungan khusus liyane, kita bakal ngonfirmasi kahanan operasi kanthi kapisah karo pelanggan.


Spesifikasi Teknis

Item Spesifikasi
Jinis piranti Low-Voltage Withdrawable Switchgear
Rated Tegangan Kerja ≤660V
Frekuensi Rated 50Hz / 60Hz
Fungsi Utama Distribusi Daya / Kontrol Motor / Kompensasi Faktor Daya
Jinis Kabinet PC / MCC / Kabinet Kompensasi
PC Circuit Breakers Seri Emax / MT / 3WN / AH / ME
Struktur MCC Laci Gedhe lan Cilik
MCC Ngalih Utama High-Breaking MCCB / Rotary Load Ngalih karo Fuse
Mode Kompensasi Manual / Otomatis / Remote
Altitude Instalasi ≤2000m
Suhu sekitar -5°C nganti +40°C
Suhu Rata-rata 24 Jam ≤+35°C
Suhu panyimpenan -25°C nganti +55°C
Suhu Short-Term Nganti +70°C kanggo ≤24h
Sistem sing ditrapake AC 50–60Hz

Parameter listrik pungkasan kudu dikonfirmasi miturut diagram baris siji pelanggan, dhaptar beban, syarat pangayoman, lan kahanan instalasi.

Cas-space Rocket Bukak Project


Project ReferenceProject Reference

Pilihan Produk

Sadurunge pesen Panel Switchgear sing Bisa Ditarik Tegangan Rendah, para pelanggan biasane menehi proyek ing ngisor iki informasi:

Informasi sing dibutuhake tujuane
Sistem Tegangan Nemtokake konfigurasi electrical dhasar
Arus mlebu Mbantu nemtokake kapasitas switchgear mlebu
Jumlah Feeders Nemtokake susunan unit fungsional kabinet
Jumlah Motor Nemtokake syarat MCC
Rating Motor Mbantu milih komponen feeder motor
Tingkat Sirkuit Pendek Nemtokake syarat pangayoman
Syarat Ganti Rugi Nemtokake konfigurasi kompensasi faktor daya
Lingkungan Instalasi Konfirmasi kahanan operasi sing ditrapake
Diagram Listrik Mbantu Usune nyiapake susunan kabinet sing cocok

Nyedhiyakake rincian kasebut ing tataran kutipan ngidini Usune ngembangake konfigurasi switchgear sing luwih akurat lan nyuda owah-owahan sing ora perlu sajrone produksi.

Ukuran Eksternal Produk

Low Voltage Withdrawable Switchgear Panel

Kabinet pusat distribusi daya (PC).

N o. barang Unit Unit ngalih beban break unit kombinasi Unit pemutus sirkuit
1 voltase dirating kV 12/24 12/24 12/24
2 frekuensi dirating Hz 50 50 50
3 Rated saiki A 630 125 (gumantung saka arus sekring) 630
4 Tingkat insulasi sing dirating 1 min Frekuensi tahan tekanan kV 42/65 42/65 42/65
48/79 48/79 48/79
2/2 2/2 2/2
Impuls cahya tahan voltase 75/125 75/125 75/125
85/145 85/145 85/145
5 Rated short circuit tahan saiki kA/s 25/4 —— 25/4
6 Rated puncak tahan saiki kA 63 —— 63
7 Rated short circuit nggawe saiki kA 63 Diwatesi dening sekring HV 63
8 Rated short circuit breaking saiki kA —— Diwatesi dening sekring HV 25/25
9 Dirating saiki transmisi A —— 1700/1400 ——
10 Rated beban aktif breaking saiki A 630 —— ——
11 Arus pemutus loop tertutup sing dirating A 630 —— 630
12 urip mekanik mbukak break switch / CB kaping 10000 10000 20000
Isolasi / switch lemah 5000 5000 5000
13 Resistance sirkuit μΩ ≤150 —— ≤150
14 Rated tekanan pengisian (20 ℃ tekanan gauge) MPa 0.04 0.04 0.04
15 Tingkat kebocoran relatif gas taunan % 0.05 0.05 0.05
16 gelar pangayoman IP Kabinet IP4X IP4X IP4X
Tangki gas IP67 IP67 IP67

B Kabinet pusat kontrol motor (MCC).

dhuwur Jembar ambane Cathetan
H B B1 B2 T T1 T2
2200 1000 600 400 600 400 200 Operasi siji-sisi
2200 1000 600 400 1000 400 200 Operasi sisih pindho

Manajemen Mutu

Kita ing Usune ngoperasikake proses manufaktur lan manajemen kualitas sesuai karo ISO 9001, ISO 14001, lan ISO 45001.

Kita ngembangake lan nggawe produk kita kanthi referensi menyang standar IEC lan GB sing ditrapake. Sertifikasi CE kasedhiya kanggo konfigurasi produk lan target pasar sing ditrapake.

Pemriksaan pabrik kita nyakup instalasi komponen, perakitan kabinet, sambungan listrik, mekanisme fungsional, lan tes rutin sadurunge dikirim.

Kita bisa nyedhiyakake dokumen teknis lan laporan tes sing cocog miturut syarat proyek.


Test ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest ReportTest Report

FAQ

Apa voltase dirating sistem?

Peralatan kasebut dirancang kanggo sistem AC kanthi voltase kerja 660V lan ngisor.

Apa fungsi sing bisa digabungake?

Sistem kasebut bisa nggabungake distribusi daya, kontrol motor, lan fungsi kompensasi faktor daya otomatis.

Apa kabinet PC?

Kabinet PC utamane digunakake kanggo panrima lan distribusi daya. Bisa diatur karo sirkuit cocok breakers miturut syarat sistem.

Apa kabinet MCC?

Kabinet MCC dirancang kanggo kontrol terpusat lan pangayoman saka macem-macem sirkuit motor. Bisa nggunakake gedhe lan konfigurasi laci cilik.

Apa peralatan bisa disesuaikan?

ya wis. Usune bisa ngatur kabinet miturut diagram baris siji pelanggan, dhaptar muatan, rating motor, jumlah feeder, lan syarat ganti rugi.

Apa standar sing ditindakake Usune?

Usune beroperasi miturut sistem manajemen ISO 9001, ISO 14001, lan ISO 45001. Produk dirancang miturut standar IEC lan GB sing ditrapake, kanthi sertifikasi CE kasedhiya kanggo konfigurasi sing ditrapake.

Apa lingkungan operasi khusus bisa didhukung?

Lingkungan khusus kayata platform lepas pantai lan fasilitas tenaga nuklir mbutuhake evaluasi teknis sing kapisah lan persetujuan sadurunge produksi.

Informasi apa sing dibutuhake kanggo kutipan?

Pelanggan dianjurake kanggo nyedhiyakake voltase sistem, arus sing mlebu, jumlah feeder, informasi motor, tingkat short-circuit, syarat ganti rugi, siji-line diagram, lan lingkungan instalasi.

Apa Usune nyedhiyakake laporan tes?

ya wis. Inspeksi pabrik lan tes rutin ditindakake sadurunge dikirim, lan laporan tes sing relevan bisa uga diwenehake miturut syarat proyek.

Kapabilitas Pasokan Usune

Usune fokus ing peralatan listrik kurang voltase lan menehi konfigurasi switchgear project-oriented kanggo industri, komersial, energi, transportasi, lan aplikasi infrastruktur khusus.

Kanggo pelanggan sing tuku Panel Switchgear sing Bisa Ditarik Tegangan Rendah, Usune bisa ndhukung proses kasebut saka listrik konfirmasi parameter lan konfigurasi kabinèt kanggo pengawasan Manufaktur lan dokumentasi kiriman, nyediakake a solusi praktis adhedhasar sistem electrical nyata tinimbang nggunakake konfigurasi padha kanggo saben project.

Kirim Pitakonan
Info kontak
Yen sampeyan duwe pitakon babagan penawaran utawa kerjasama, aja ragu-ragu ngirim email utawa gunakake formulir pitakon ing ngisor iki. Wakil sales kita bakal ngubungi sampeyan sajrone 24 jam.
Rating:
5.0
X
Kita nggunakake cookie kanggo menehi pengalaman browsing sing luwih apik, nganalisa lalu lintas situs lan nggawe konten pribadi. Kanthi nggunakake situs iki, sampeyan setuju kanggo nggunakake cookie. Kebijakan Privasi
nolakNampa